Titanium Hemostatic Clip Tailoring Method to Overcome Vessel Caliber Discrepancy in Interposition Saphenous Vein Graft for Carotid Artery Resection
Sun Ho Kim;Young Chang Lim;Sei Young Lee;Jae Yol Lim;Eun Chang Choi
경동맥 절제술 후 재건에 사용된 복재정맥의 혈관구경 불일치를 극복하기 위한 Titanium Hemostatic Clip 봉합방법
김선호;임영창;이세영;임재열;최은창
Abstract
Objectives: To completely excise a malignant tumor which invades carotid artery walls, the resection and reconstruction of the carotid artery is essentially required. In most of the cases, interposition graft using a saphenous vein has been performed, however the vessel caliber discrepancy between a common carotid artery and the saphenous vein can result in a problem on surgical technique. We have introduced and evaluated a new titanium hemoclip tailing method to overcome vessel caliber discrepancy in interposition saphenous vein graft for carotid artery resection in the treatment of head and neck cancers. Method: After carotid artery resection, the calibers of the proximal common carotid artery and the vein were compared, and an orifice of the common carotid artery was gradually reduced to a little larger than or the same size as the orifice of the vein by using the titanium hemostatic clip. Subsequently, the common carotid artery was connected to the vein through anastomosis. The same method was also applied to the distal anastomosis site. There after, the vessels were connected through the anastomosis, and a circulation was restored by releasing a vascular clamp. Then, a titanium hemostatic clip-applied redundant portion on the outside of carotid artery was sutured by the blanket edge suture method, using 6-0 Prolene.
Results
We have experienced this method in two patients with recurrent squamous cell carcinoma and neuroblostoma, respectively. The interposition saphenous vein graft of these patients was found to maintain good patency on the follow up angiography after one year, and they had no specific vascular complication, such as atherosclerosis.
Conclusion
This method made it possible to simply perform the interposition saphenous vein graft (ISVG) within a short time and, therefore, was very useful for shortening the duration to block circulation.
Key Words: Interposition saphenous vein graft (ISVG), Carotid resection, Malignant tumor, Head & neck cancer, Titanium hemostatic clip
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 163 View
  • 0 Download
Related articles in Korean J Head Neck Oncol


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
EDITORIAL POLICY
AUTHOR INFORMATION
Editorial Office
327, Sosa-ro, Bucheon-si, Gyeonggi-do 14647, Korea
Tel: +82-10-9810-7671    Fax: +82-504-223-7671    E-mail: kshno@hanmail.net                

Copyright © 2021 by Korean Society for Head & Neck Oncology.

Developed in M2PI

Close layer
prev next